From raw material to electrical testing, under one roof

Silicon steel, enameled copper, core, insulation, resin and electrical testing: every stage of making a Toroid transformer or inductor happens inside our own plant, in São José dos Pinhais, with lot traceability from start to finish.

Raw materials

Grain-oriented silicon steel and enameled copper, to the right specification

The core starts from grain-oriented silicon steel laminations in M3 (0.23 mm) and M4 (0.27 mm) thicknesses, cut to widths from 10 mm to 80 mm according to each project's specification. This high magnetic permeability lamination is what sustains the electrical performance declared for each line.

The winding uses G2 enameled copper, with high insulation and conductivity, in gauges from 5 AWG to 36 AWG. The full range covers everything from low-current instrumentation circuits to windings that must carry heavier loads, without changing supplier from one end of the line to the other.

Coils of grain-oriented silicon steel stored at the Toroid factory
Coils of enameled copper wire stored at the Toroid factory

Cores and heat treatment

Cores made in-house, with their own heat treatment

Toroidal cores, with an outer diameter from 15 mm to 350 mm, and custom rectangular cores are made inside the plant itself, with no dependence on an outside supplier at this stage.

After winding, each core goes through heat treatment in a nitrogen atmosphere, with a heating ramp of up to 820 °C. The process drives out oxygen, fixes the core geometry and restores the electrical and magnetic properties of the steel, which are altered by the cutting and winding themselves.

Core being manufactured at the Toroid factory

Insulation, winding and resin

From insulation to encapsulation, cell by cell

8 machines apply polyester film (Mylar) in widths of 6, 10, 17 and 25 mm, and 18 winding machines, organized by cell according to wire gauge and core size, cover production from the smallest to the largest component in the line.

Dipping in varnish and resin strengthens electrical insulation, eliminates vibration and reduces audible noise. Partial or full resin coating increases the mechanical strength of voltage transformers, and encapsulation reinforces the dielectric and environmental protection of current transformers.

Winding machine applying copper wire to a toroidal core
Parts being dipped in varnish and resin at the Toroid factory

CNC, tooling and production control

In-house tooling and lot traceability

In-house CNC machines produce molds for resin encapsulation, nameplates and mounting and fastening components, with an internal workshop dedicated to preventive maintenance and continuous adjustment of the equipment.

Production planning and control is automated, with barcode scanning at every stage, for full lot traceability, from winding to the final electrical test.

Operator machining a component on a CNC machine at the Toroid factory

Test laboratory and quality

Rigorous electrical testing, piece by piece

Every transformer and inductor goes through a complete electrical test before leaving the factory, with instrumentation connected to each piece to ensure technical compliance with the original specification.

It is the same discipline that supports a certified management system, and that gives the customer's engineering field data it can trust without a margin of doubt. Get to know the engineering applied to every Toroid do Brasil transformer.

Toroidal cores connected to electrical test instruments in the Toroid laboratory

Before shipment

100% of parts electrically tested, no sampling

Every transformer and inductor produced goes through the laboratory before leaving the factory. It is the same standard that supports the ISO 9001 certification, issued by RINA.

  • No-load voltage and current
  • Error and saturation behavior
  • Phase angle
  • Inductance and insulation
  • Polarity

Technical quote

Send the specification, or just the panel's constraint. Our team replies with the sizing.

Voltage, current, available space and applicable standard. If any data point is still missing, our team helps you pin it down.

Talk to our team
Talk to a specialist