Brazilian engineering · ISO 9001
Excessive electrical noise shouldn't compromise signal readings.
A lower stray magnetic field keeps the signal clean, free of electrical interference. Discover the engineering applied to every Toroid do Brasil transformer.
- São José dos Pinhais · PR
- 100% custom products
- 3-year warranty
Products
Standard line and custom-engineered projects.

Current Transformers
Measurement and protection with an accuracy class defined by application, from the distribution panel to the bench instrument.
View specifications
Power Transformers
Insulation, voltage and efficiency calculated for your equipment, with documented electrical testing before shipment.
View specifications
Inductors & Reactors
Filtering and current limiting with inductance specified over a real operating range, not a single nominal value.
View specifications
Isobox
Standard-line current transformer, ready for the three most common panel mounting types: DIN rail, panel back plate or busbar.
View specificationsSegments served
Each application imposes a different constraint. The design starts there.
Medical equipment manufacturers
Shielding between windings and low leakage current: less interference in the measured signal, a reliable test report and test approval without redesign.
View applicationUPS systems and power conditioners
Lower no-load loss and a contained stray magnetic field: less heat inside the enclosure, autonomy preserved in the field and fewer warranty claims.
View applicationIndustrial automation
Toroidal core with no air gap and reduced volume: fits the designed panel, stable temperature inside the panel and fewer line stops from thermal failure.
View applicationLaboratory equipment
Reduced acoustic and magnetic noise: stable instrument reading, repeatability between tests and less unplanned recalibration.
View applicationElectrical system integrators
Custom sizing per application: field installation with no on-site adaptation, project schedule kept and less overtime for your own team.
View applicationToroidal core performance
Stability that shows up in the equipment, not in the catalog.
These characteristics come from the toroidal geometry. Current transformers and inductors follow their own principles, each sized for the role it plays in the design.
Higher energy efficiency
Magnetic flux closed within the core itself reduces no-load loss: less energy dissipated per hour running, lower operating cost for the end customer and a verifiable point in the proposal.
Lower stray magnetic field
Toroidal geometry with no air gap contains the field: less interference with neighboring boards, more freedom in layout inside the enclosure and fewer layout revisions mid-project.
Lower acoustic noise
Tape-wound core, with no stacked laminations, eliminates audible vibration: quiet equipment in occupied rooms and fewer operator complaints in the field.
Lower heating
Winding distributed across the whole circumference dissipates better: lower steady-state temperature, longer life for nearby components and fewer warranty replacements.
In-house manufacturing
32 years transforming energy and lives.
Winding, encapsulation and electrical testing done in São José dos Pinhais, with batch traceability and a certified management system. We supply global leaders in the electrical and industrial sectors.



Technical quote
Send the specification, or just the panel's constraint. Our team replies with the sizing.
Voltage, current, available space and applicable standard. If any data point is still missing, our team helps you pin it down.

